Pular para as informações do produto
1 de 5

WhatsApp: 8613682321223

5.5-inch Touch Screen Portable Patient Monitor Medical, Small, Simple Operation, Easy to Carry, Suitable for a Variety of Places

5.5-inch Touch Screen Portable Patient Monitor Medical, Small, Simple Operation, Easy to Carry, Suitable for a Variety of Places

Preço normal $299.00 USD
Preço normal $389.00 USD Preço promocional $299.00 USD
Promoção Esgotado
Frete calculado no checkout.

Portable Patient Monitor

MUlti-function 5 in 1 patient monitor medical, Portable 3 channel ECG holter ecg device machine blood pressure monitor with analyzer clinical analytical Instruments.

Specification

ECG, blood pressure, blood oxygen, body temperature, breathing monitoring.

1. 5.5-inch touch screen, resolution : 1280*720
2. Capacitive touch screen, easy to use
3. WIFI module, Can connecting vecare app or central monitoring systems
4. Volume size : 15cm * 8cm * 5.5cm
5. The whole machine can work 6 hours with lithium battery power supply
6. Total weight : 400 g
7. TYPE-C USB cable
8. Optional : ETco2

Multiple Display Interfaces

ECG(RESP), NIBP, Spo2(HR), TEMP

Advantage

1. Small, simple operation, easy to carry, Suitable for a variety of places
2. Multiple parameters
3. High accuracy and good consistency
4. App communication, suitable for mobile medical, Health
data management and analysis
5. Comply with the national and industry-related standards

ECG EKG

1. gain selection: 2.5mm/mV;5.0 mm/mV;10mm/ mV;20mm/mV;

2. lead type: 3 channel.

NIBP Blood Pressure

1. measurement mode: automatic measurement, continuous measurement, manual measurement three modes;

2. support over voltage protection;

3. static pressure measurement: in the range of 0mmHg (0KPa) ~ 300mmHg (40.0KPa), the measurement error should be 3mmHg (± 0.4kpa);

4. measurement accuracy:the maximum standard error ±5mmHg, the maximum standard deviation 8mmHg;

5. resolution: display resolution should be 0.1kpa (1 mmHg>) .

SPO2 Oxygen Saturation

1.Blood pressure saturation measurement range :0% ~ 100%;

2. measurement accuracy: within the range of 90%-100% accuracy should be ±1%.

Pulse Frequency

1.Measurement range: the blood oxygen pulse rate ranges from 20bpm to 250bpm, and the measurement error should be ±3bpm;TEMP temperature1, high sensitivity temperature probe;

2, the measurement range :O℃ ~ 50℃: the measurement error does not include the probe is ±0.1℃, including the probe is ±0.2℃.

Product List

Multifunctional monitor, adult blood pressure cuff, high precision temperature probe, 3-wire ECG, blood oxygen probe.

Ver informações completas